saimo Load cell PLR9363-LS/PLR9363-CS/PLR9363-AS
Use and characteristics
One end fixed, one end loaded, sealed well;;
Automatically adjusted by the force of the heart, simple to install, easy to use, good interchangeability;
It can be used for the production of ultra-thin electronic truck scale, monorail crane scale, hopper scales, etc. .
Range
50,100,200,300,500 kg; 1,2,3,5,10,15,20 t
cantilever weighing sensor technology parameters
Rated load |
0.05 to 20t |
Comprehensive accuracy |
0.02 0.03 (linear + lag + repeatability) |
Sensitivity |
2.0 mV / V |
Creep |
± 0.02% F · S / 30min |
Zero output |
± 1% F · S |
Zero temperature effect |
± 0.02% F · S / 10 ¡æ |
Output temperature |
± 0.02% F · S / 10 ¡æ |
Operating temperature |
-20 ° C to + 65 ° C |
Input resistance |
380 ± 10 Ω |
Output impedance |
350 ± 3 Ω |
Insulation resistance |
> 5000 MΩ |
Safety overload |
150% F · S |
For the bridge voltage |
Recommended 10VDC |
Material |
Alloy steel or stainless steel |
Wiring |
Input (+): Red line input (-): Black line |
Output (+): Green line output (-): White line |
|
Signal amplifier wiring |
Power: Red Common: Green Output: Yellow |